pepmg_

Study summary · research use only

Fully automated dried blood spot sample preparation enables the detection of lower molecular mass peptide and non-peptide doping agents by means of LC-HRMS

Study · human · Analytical and bioanalytical chemistry · 2020 · DOI 10.1007/s00216-020-02634-4 · PMID 32300840

Plain-language summary

Paraphrased from the published abstract below — not a verdict on whether anything works.

This analytical method-development study (species not specified) describes a fully automated dried blood spot (DBS) sample preparation approach, combining near-infrared hematocrit measurement with solid-phase extraction, for detecting lower molecular mass peptide and non-peptide doping agents by LC-HRMS. The authors report detection of 46 lower molecular mass (<2 kDa) peptide and non-peptide drugs and candidates, including agonists of the gonadotropin-releasing hormone receptor, ghrelin receptor, growth hormone receptor, and antidiuretic hormone receptor, plus glycine derivatives of growth hormone-releasing peptides (GHRPs). The assay was validated per World Anti-Doping Agency guidelines with estimated limits of detection between 0.5 and 20 ng/mL, and authentic post-administration specimens containing GHRP-2 and GHRP-6 were analyzed, along with DBS from a microneedle sampling device.

Abstract

The added value of dried blood spot (DBS) samples complementing the information obtained from commonly routine doping control matrices is continuously increasing in sports drug testing. In this project, a robotic-assisted non-destructive hematocrit measurement from dried blood spots by near-infrared spectroscopy followed by a fully automated sample preparation including strong cation exchange solid-phase extraction and evaporation enabled the detection of 46 lower molecular mass (< 2 kDa) peptide and non-peptide drugs and drug candidates by means of LC-HRMS. The target analytes included, amongst others, agonists of the gonadotropin-releasing hormone receptor, the ghrelin receptor, the human growth hormone receptor, and the antidiuretic hormone receptor. Furthermore, several glycine derivatives of growth hormone-releasing peptides (GHRPs), arguably designed to undermine current anti-doping testing approaches, were implemented to the presented detection method. The initial testing assay was validated according to the World Anti-Doping Agency guidelines with estimated LODs between 0.5 and 20 ng/mL. As a proof of concept, authentic post-administration specimens containing GHRP-2 and GHRP-6 were successfully analyzed. Furthermore, DBS obtained from a sampling device operating with microneedles for blood collection from the upper arm were analyzed and the matrix was cross-validated for selected parameters. The introduction of the hematocrit measurement method can be of great value for doping analysis as it allows for quantitative DBS applications by managing the well-recognized "hematocrit effect." Graphical abstract.

Read the full study on PubMed ↗ Open-access full text ↗

pepmg summarizes the peer-reviewed literature and links to every source — it sells nothing, ships nothing, and gives no medical, dosing, or human-use guidance. Don't just trust this summary: follow the citation to its source and read it yourself. Research use only.