pepmg_

Study summary · research use only

Rapid Analysis of Urinary AICAR by Liquid Chromatography-Isotope Ratio Mass Spectrometry

Study · human · Analytical chemistry · 2026 · DOI 10.1021/acs.analchem.5c07661 · PMID 41955491

Plain-language summary

Paraphrased from the published abstract below — not a verdict on whether anything works.

This study developed and validated a liquid chromatography-isotope ratio mass spectrometry (LC-IRMS) method to distinguish endogenous from synthetic AICAR in human urine, using solid-phase extraction and 2D-LC cleanup, with etiocholanolone and androsterone as endogenous reference compounds, following World Anti-Doping Agency (WADA) validation requirements. The abstract reports that in a reference population of n = 50, thresholds for declaring an adverse analytical finding were determined at 6.9‰ for AICAR-etiocholanolone and 5.8‰ for AICAR-androsterone, roughly 2‰ lower than thresholds previously reported using gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS).

Abstract

5-Aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR) is prohibited in sports according to the World Anti-Doping Agency (WADA). Currently, AICAR concentrations are measured during the initial testing procedure, and urine samples showing elevated levels are flagged as suspicious and forwarded for confirmation. Here, gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) is employed to distinguish endogenous from exogenous AICAR, as synthetic AICAR exhibits a different carbon isotope ratio (CIR). However, a GC-C-IRMS method comes with multiple challenges as AICAR is very polar, making it particularly difficult to analyze using GC. It is clear that there are a number of issues related to the existing protocol, and efforts should be made to develop new, more effective, and less expensive approaches. For polar substances, liquid chromatography-isotope ratio mass spectrometry (LC-IRMS) provides a more straightforward approach. There is no need for derivatization, AICAR can be directly analyzed with LC-IRMS, and many GC-C-IRMS related issues are avoided. LC-IRMS also allows condensing of the workflow and lowering of the turnaround time. In this study, a rapid protocol for AICAR CIR determination was developed, employing solid-phase extraction and 2D-LC cleanup prior to LC-IRMS analysis. Etiocholanolone and androsterone were used as endogenous reference compounds, and the method was fully validated according to WADA regulations. Reference population (n = 50) thresholds, used to declare an adverse analytical finding (AAF, i.e., a positive AICAR sample), were determined (6.9‰ and 5.8‰ for AICAR-etiocholanolone and AICAR-androsterone, respectively) and found to be approximately 2‰ lower than those previously reported using GC-C-IRMS, facilitating AAF identification.

Read the full study on PubMed ↗

pepmg summarizes the peer-reviewed literature and links to every source — it sells nothing, ships nothing, and gives no medical, dosing, or human-use guidance. Don't just trust this summary: follow the citation to its source and read it yourself. Research use only.